Hartip 3000
Hardness Tester Hartip 3000 - Standardpaket - Specifications for Leeb Portable Hardness Tester - Hartip 3000 - Portable Hardness Tester: • Accuracy: +/- 0.5% (referred to L = 800; repeated accuracy = +/ - 4 L units) • Measuring range: 200 to 970HL • Materials: Wrought and cast steel;, Alloy tool steel, Stainless steel, Gray cast iron, Nodular cast iron, Cast aluminum, Brass, Bronze, Wrought copper alloy • Batteries: four 1.2/1.5 VAA dry batteries or rechargeable batteries • Operating temperature -10 to +45°C (14 to 113°F) • Dimensions: 195 x 84 x 38mm (7.7 x 3.3 x 1.5 in.) • Weight: Basic unit 550g (1.21 lbs)
3.087,00 €*
HARTIP 1900
Härtemessgerät Hartip 1900 ( Rückprallhärteverfahren ) Lieferumfang: Gerät Hartip 1900, Schlagkörper G, USB Kabel, Ladegerät, Datentransfer Software, Herstellerzertifikat und KofferBedienungsanleitung .
1.750,00 €*
portable hardness tester novotest T-UD3
portable hardness tester novotest T-UD3 mit einer Sonde (wahlweise UCI oder Leeb) Technical Specifications: UCI probe types 1kgf (9,8N),, 5kgf (49N), 10kgf (98N) Leeb probe types D, DC, DL, C, D+15, E, G Measuring range HV:230~940; HRC:20~70; HB:90~650. Tensile strength, MPa 370~1740User calibrations for any range (for example: HV100-1600) Measuring accuracy HV:±3%HV; HRC:±1.5%HRC; HB:±3%HB Standards ASTM A1038, ASTM A956, ASTM E140 Indenter 2 Diamond indenter (UCI) (50N ; 98N), Hardened ball (Leeb) Measuring direction Any direction 360° Data storage Limited only by the memory card up to 32Gb Communication Upload data to PC and export as a spreadsheet (USB cable and software included ) Hardness scales UCI probe – HRC, HB, HVLeeb probe – HRC, HB, HV, HRB, MPaAdditional custom scales for calibration. Materials Ultrasonic (UCI) probe – pre-calibrated for steel.Dynamic (Leeb) pre-calibrated for steel, alloy steel, cast iron, stainless steel, aluminum, bronze, brass, copper.Additional custom materials for calibration. Data display Load applied/contact (UCI), Angle (Leeb), Single test result, Max, Min, Average of tests, Number of tests, Deviation, Var. coeff, Histogram, Signal and Smart Mode (Filter of incorrect measurements). Indication Color LCD display (320×240) Operating environment Temperature:-20°C~40°C; Humidity: 30%~80%R.H. Power supply DC 4,5V (3 pcs batteries AA) Instrument dimensions 160x75x30mm Net weight Approx. 0.3kg (without probe) Battery life Approx. 10 hours. Wir bitten bei der Bestellung uns kurz Ihre Sondenauswahl mit aufzugeben! Danke !!!
2.900,00 €*
Krautkrämer Dyna Mic
Krautkrämer Dyna Micbestehend aus: Kontrollkörper D ( 768 HLD ) , Schlaggerät D, Bedienungsanleitung und Kabel im Koffer Neupreis: ca. 5000,00 Euro
2.600,00 €*
Vickers (UCI) Härtevergleichsplatte 80x16mm 517
Abmessung Ø80x16mm Härtewert ca. 517 Prüflast HV 5 Ohne (zertifikat)
250,00 €*
Vickers (UCI) Härtevergleichsplatte 80x16mm 518
Abmessung Ø80x16mm Härtewert ca. 518 Prüflast HV 5 Ohne (zertifikat)
250,00 €*